  1. The "N" in the THHN/THWN - ECN Electrical Forums

    Jul 26, 2009 · I know the "N" stands for Nylon. By reading articles and other code sections i assume if the nylon is broken or damaged then the THHN conductor can not be used in a …

  2. Southwire SIM PULL cable - ECN Electrical Forums

    Apr 26, 2007 · We just pulled in about 5900' of 500 MCM that had Southwires new SIM PULL insulation. It was marked no lube, but at runs of 470' I wasn't taking any chance not using lube. Has anyone …

  3. Feeders -- Colored or black with ID markings? - ECN Electrical Forums

    Jul 5, 2008 · I used to always specify colored cable whenever possible. Many suppliers are getting away from stocking multiple colors, so I'm pretty much stuck using marking tape now. I do like Southwire's …

  4. Southwire SIM PULL cable - ECN Electrical Forums

    Apr 26, 2007 · The Southwire rep. says they guarantee their product, but it will take a little getting use to before I give up using wire lube, especially when pulling big wire.

  5. COMPARING RW90 & T90/TWN75 - Electrical Contractor

    COMPARING RW90 & T90/TWN75 .). In sizes #14 to #6 T90/TWN75 still has a smaller O.D. In sizes #4 and larger RW90 now has an O.D. slightly less than T90/TWN75. This may result in a smaller …

  6. wet location - ECN Electrical Forums

    Dec 31, 2009 · Originally Posted by gfretwellI suppose the AHJ makes the rules but article 100 says wet locations are "... unprotected locations exposed to weather". In 2008 they also removed …

  7. MC cable in a damp location - ECN Electrical Forums

    Do we have any information that makes it clear about running MC cable in a damp location. I can find wet locations and dry but nothing on a damp location?

  8. Romex outside - ECN Electrical Forums

    Jul 25, 2009 · I've got a picnic shelter I'm giving a price on that will include lighting and a few receptacles. The wiring will not be exposed to the direct weather but will be exposed to humidity. Can …

  9. megging/testing a 3 phase 480V 10HP wye motor

    Jan 9, 2002 · I'm an electrician working for a major university. I was told by our stationary engineer to meg out a motor because he was getting "ground fault" errors on his VFD. I said okay I'll …

  10. humidistat - ECN Electrical Forums

    Feb 19, 2011 · Has anyone installed a humidistat on the ceiling of a bathroom? A consultant wants to put in new fans, with a humidistat mounted on the ceiling, and a digital timer so that when it gets too …